Distribution Line Earth Fault Indicator Monitoring Device for Underground Networks

Sold by:

Four-Faith Smart Power Technology Co.,Ltd.

Request a quote

CHARACTERISTICS

Company Website

Company Contacts

Contacts Email

Contacts Mobile Number

Company Address

DESCRIPTION

Distribution Line Earth Fault Indicator Monitoring Device for Underground Networks

The DJX-FF-C Earth Fault Indicator for MV Power Distribution Network is used in 6~35KV Cable line power distribution networks, usually installed in Ring Main Unit, Cable Distribution Box, Switch Cabinet, enable the electricity distribution network engineers to quickly identify the faulty section of network and restore power supplies to customers on healthy sections in the shortest time possible.


Features


Short Circuit Warning Current: 200-2000A Selectable (accuracy:±10%); Delay 20-300ms; Customer could select before production; Default Settings: 800A/20ms


Earth Fault Warning Current: 10-150A Selectable (accuracy:±10%); Delay 20-300ms; Customer could select before production; Default Settings: 20A/20ms


Short circuit sensor mounted cable diameter: outside diameter≤Φ40mm (other specifications shall be customized)


Earth fault sensor mounted cable diameter: outside diameter≤Φ120mm (other specifications shall be customized)


Working Ambient Temperature: -40℃-75℃


Relative Humidity: ≤95%RH


Working Power Supply: The sensors are powered by the CT when the flowing current above 10A, when the current under 10 A, will powered by the backup Lithium battery; The display unit is powered by the Lithium Battery


Remote Signal Communication Reset Method: Manual reset / Auto reset


Automatic Reset Time: 1-48H Selectable (accuracy:±1%); Customer could select before production; Default Settings: 12H


Suitable for medium voltage below 35KV rating system.


System Composition


The system is composed of 3 pcs short circuit sensor, 1 pcs earth fault sensor, and 1 pcs Display Unit.


1. Sensor


4pcs/SET, include 3 pcs short circuit sensors and 1 pcs earth fault sensor. 3 pcs short circuit sensors respectively installed in A,B,C three phase Cable Line, 1 pcs earth fault sensor installed on the bifurcation unshielded part of three-phase cable.


2. Display Unit


Receive fault signal from sensors and display immediately as light flashing. The sensors and the display unit is connected by the fiber optic.

Operation Worked Example


1. Short circuit indication:


On detection of flowing current value exceed the fault sensitivity threshold, the Short circuit sensor will send fault signal through fiber optic to the Display Unit. The Display Unit will respond by light flashing in the short circuit indicator.


2. Earth fault indication:


On detection of the zero sequence current value exceed fault sensitivity threshold, the earth fault sensor will send fault signal through fiber optic to the Display Unit. The Display Unit will respond by light flashing in the earth fault indicator.

.content_format table{border:1px solid #dedede; border-collapse:collapse;} .content_format td{ padding:3px; border: 1px solid #dcdcdc; } .content_format { line-height: 24px; word-wrap : break-word ; } .content_format p{ margin-bottom: 10px; margin-top: 2px; padding: 2px; }

Quality Distribution Line Earth Fault Indicator Monitoring Device for Underground Networks for sale

Distribution Line Earth Fault Indicator Monitoring Device for Underground Networks

Electronic manufacturing network
Sign In
Join Free
LOGIN
REGISTER